Automated Fat / Oil Analysis

Automated Fat / Oil Analysis

ANKOM XT15 Extractor - 120v

The ANKOMXT15 Extractor provides an Official Procedure for efficient and economical solvent extractions.The ANKOMXT15 Extractor has been subjected to rigorous testing over a broad range of sample types. Fat ranges from 0% to 100% have been determined using this procedure.

The XT15 Extractor provides a totally automate system capable of approximately 150 extractions per day and recovers solvent at a rate of 97%.

Official Method - AOCS Am 5-04

 

 

Automated Fat / Oil AnalysisANKOM XT15 Extractor - 220v

The ANKOMXT15 Extractor provides an Official Procedure for efficient and economical solvent extractions.The ANKOMXT15 Extractor has been subjected to rigorous testing over a broad range of sample types. Fat ranges from 0% to 100% have been determined using this procedure.

The XT15 Extractor provides a totally automate system capable of approximately 150 extractions per day and recovers solvent at a rate of 97%.

Official Method - AOCS Am 5-04

 

ANKOMXT15 Extractor - Overview

  • Official Crude Fat Procedure – AOCS Am 5-04
  • Totally Automatic Operation
  • Up to 150 Extractions per Day
  • Microprocessor Controlled with LCD Readout
  • Solvent Recovery at a rate of ~97%
  • Solvent Usage per Sample ~ 0.5 ml
  • No Vent-hood Required

Applications & Information

The ANKOMXT15 Extractor provides an Official Procedure for efficient and economical solvent extractions.The ANKOMXT15 Extractor has been subjected to rigorous testing over a broad range of sample types. Fat ranges from 0% to 100% have been determined using this procedure.

The XT15’s low cost provides an affordable high-volume solution. Batch processing allows for the extraction of up to 15 samples at a time and is capable of more than 150 samples per day. Also 90°C temperatures accelerate extraction kinetics, reducing most extraction times to under 40 minutes.

Filter bags serve to simplify handling and enable batch processing. The XT15’s Automatic Solvent Recycling and Activated Charcoal Filter elminates the need for a vent hood and reduces costs.

Features & Benefits

Approved Procedure - AOCS Am 5-04
- Assures accuracy of results
- Can be used to calibrate NIR and other
  secondary methods
Automatic Operation - Microprocessor Controlled with LCD display
- Limited technician involvement
- No advanced training required
Filter Bag Technology - Enables batch processing, up to 15 samples/time
- 150 samples/day
- Increases precision and accuracy
Automatic Solvent Recycling - No vent hood required
- Saves money
- Virtually eliminates solvent handling
90°C Extraction Temperature - Accelerates extraction kinetics
- Greatly reduces extraction time
- Increases throughput
Small Footprint - Saves valuable lab space
 
 
 
 
XT10B.jpgANKOM XT10 Extractor - 120v

The XT10 Extractor provides a lower cost semi-automatic system capable of approximately 100 extractions per day and recovers solvent at a rate of about 90%

Official Method - AOCS Am 5-04

 

 

 

XT10B.jpgANKOM XT10 Extractor - 220v

The ANKOMXT10 Extractor provides an Official Procedure for efficient and economical solvent extractions. The ANKOMXT10 Extractor has been subjected to rigorous testing over a broad range of sample types. Fat ranges from 0% to 100% have been determined using this procedure.

The XT10 Extractor provides a lower cost semi-automatic system capable of approximately 100 extractions per day and recovers solvent at a rate of about 90%

Official Method - AOCS Am 5-04

 

ANKOMXT10 Extractor - Overview

  • Official Crude Fat Procedure - AOCS Am 5-04
  • Low Cost & Easy-to-use
  • Up to 100 Extractions per day
  • Solvent Recovery at a rate of ~90%
  • Microprocessor Controlled with LCD Readout
  • Filter Bag Technology
  • Small Footprint

Applications & Information

The ANKOMXT10 Extractor provides an Official Procedure for efficient and economical solvent extractions. The ANKOMXT10 Extractor has been subjected to rigorous testing over a broad range of sample types. Fat ranges from 0% to 100% have been determined using this procedure.

The XT10’s low cost provides an affordable high-volume solution. Batch processing allows for the extraction of up to fifteen samples at a time and up to 100 samples per day. A process temperature of 90°C accelerates extraction kinetics, reducing most extraction times to under 40 minutes.

Samples are placed into filter bags which prevent sample transfer error. Filter bags serve to simplify handling and enable batch processing. The XT10 automatically recycles solvent and makes it ready for reuse. Solvent is manually added after each extraction.

Please see the operators manual for details on the procedures for various sample classifications.

Features & Benefits

Approved Procedure - AOCS Am 5-04
- Assures accuracy of results
- Can be used to calibrate NIR and other
  secondary methods
Low Cost - Lowers cost per sample
- Low entry cost
Filter Bag Technology - Enables batch processing, up to 15 samples/time
- 100+ samples/day
- Increases precision and accuracy
Solvent Recycling - Saves money
- Reduces solvent usage and waste disposal
- Environmentally Friendly
Simple Operation - Microprocessor controlled with LCD display
- No advanced training required
- Saves labor costs
90°C Extraction Temperature - Accelerates extraction kinetics
- Greatly reduces extraction time
- Increases throughput
Small Footprint - Saves valuable lab space